Skip to content

Filipino Engineer

Menu
  • Blog
  • Wiki
  • Archives
    • Page Archives
  • Downloads
    • Disclaimer
  • Tutorials
    • Standards
    • Design
    • EE101
  • Contact

Tag: Circuit Breaker

Design / IEC / IEEE / Protection / Standards

IEEE C37 and IEC 62271: Comparative Analysis of High Voltage Circuit Breaker Standards

The IEEE C37 and IEC 62271 standards define the electrical and mechanical requirements for high voltage circuit breakers and switchgear, including their ratings, performance, features, and testing protocols. Their primary …

Design / Protection / Safety

Miniature Circuit Breaker fitted with 50BF Device

I. General Considerations In certain situations, an Electrical Engineer may encounter a project requiring a miniature circuit breaker (MCB) to be equipped with a 50BF device for breaker failure protection. …

Design / Protection

Comparison of Tripping Characteristics for Miniature Circuit Breakers (MCBs)

Miniature Circuit Breakers (MCBs) are essential for protecting electrical circuits from overcurrent, short circuits, and faults. The tripping characteristics of MCBs define how quickly they disconnect a circuit based on …

Design / Protection

Non-Trip Circuit Breakers – Standards, Applications, and Comparisons

 1. Comparison of Non-Trip Circuit Breakers vs. Standard Circuit Breakers 1.1 Key Differences in Design and Function Feature Non-Trip Circuit Breaker Standard Circuit Breaker Automatic Tripping No (manual intervention required …

Design

Trip-Free Circuit Breaker – Definition, Applications and Standards

I. Definition A trip-free circuit breaker is a type of circuit breaker that cannot be manually held in the “ON” position when an electrical fault occurs. It will automatically trip …

Design / Protection

Low Voltage Circuit Breaker Selection Criteria

The selection of any low voltage circuit breaker, for any given duty, is ultimately based on an assessment of its ability to perform the following basic functions: To carry the …

Posts navigation

Older posts

Latest Posts

  • Significance of the K Factor in High Voltage Circuit Breaker Ratings
  • IEEE C37 and IEC 62271: Comparative Analysis of High Voltage Circuit Breaker Standards
  • Paralleling Dissimilar Generators: Requirements, Issues, Compatibility, and Load Sharing
  • VLF Test – Applications, Advantages and disadvantages, Alternatives and Standards
  • Core Balance Current Transformer – Applications, Alternatives and Standards

Archives

  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • October 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • March 2020
  • January 2020
  • November 2019
  • October 2019
  • September 2019
  • November 2018
  • September 2018
  • May 2017
  • April 2017
  • April 2016
  • November 2015
  • October 2015
  • July 2013
  • December 2011
  • July 2011
  • June 2011
  • October 2009
  • January 2009
Copyright © 2025 Filipino Engineer – OnePress theme by FameThemes