Skip to content

Filipino Engineer

Menu
  • Blog
  • Wiki
  • Archives
    • Page Archives
  • Downloads
    • Disclaimer
  • Tutorials
    • Standards
    • Design
    • EE101
  • Contact

Author: Ver Pangonilo

A Filipino Engineer, Registered Professional Engineer of Queensland (RPEQ) - Australia, and Professional Electrical Engineer (PEE - 1st Place April 1991) - Philippines with extensive experience in concept selection, front-end engineering, HV & LV detail design, construction, and commissioning of Hazardous and Non-Hazardous Area electrical installations in water and wastewater pipeline and pumping facilities, offshore platforms, hydrocarbon process plants and pipelines including related facilities. Hazardous area classification and design certification (UEENEEM015B, UEENEEM016B, UEENEEM017B).
Power Line
Design

Importance of Surge Impedance Loading (SIL) in Transmission Lines

Introduction The demand for power is steadily increasing every year, leading to a growing gap between power supply and demand. This gap can be addressed by either adding new generation …

ANSI / Design / IEEE / Standards

Significance of K factor in High VoltageCircuit Breaker Ratings

High Voltage Circuit Breaker Interrupting Rating The interrupting ratings of a high-voltage circuit breaker are primarily defined by two parameters: the rated short-circuit current, I, and the rated maximum voltage, …

Design / PEC

Philippine Electrical Code – Ambient Correction Factor for Cables

Temperature in the Philippines According to PAGASA data, the average mean annual temperature across all weather stations in the Philippines, excluding Baguio, is 26.6°C. The coolest month is January, with …

Design / PEC

Philippine Electrical Code – Objectionable Current

What is Objectionable Current? The term “objectionable current” in the context of the Philippine Electrical Code (PEC) refers to the presence of current flow on grounding conductors or grounding paths …

Design / PEC

Philippine Electrical Code – General Requirements for Grounding and Bonding

Performance-based requirements establish overall objectives without prescribing specific methods to achieve them. The opening paragraph of Section 2.50.1.4 explains that the performance objectives outlined in 2.50.1.4(A) for grounded systems and …

Design / PEC

Philippine Electrical Code – Separately Derived System

The PEC has defined a Separately Derived System as an electrical source, other than a service, having no direct connection(s) to circuit conductors of any other electrical source other than …

Posts navigation

Older posts
Newer posts

Latest Posts

  • Significance of the K Factor in High Voltage Circuit Breaker Ratings
  • IEEE C37 and IEC 62271: Comparative Analysis of High Voltage Circuit Breaker Standards
  • Paralleling Dissimilar Generators: Requirements, Issues, Compatibility, and Load Sharing
  • VLF Test – Applications, Advantages and disadvantages, Alternatives and Standards
  • Core Balance Current Transformer – Applications, Alternatives and Standards

Archives

  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • October 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • March 2020
  • January 2020
  • November 2019
  • October 2019
  • September 2019
  • November 2018
  • September 2018
  • May 2017
  • April 2017
  • April 2016
  • November 2015
  • October 2015
  • July 2013
  • December 2011
  • July 2011
  • June 2011
  • October 2009
  • January 2009
Copyright © 2025 Filipino Engineer – OnePress theme by FameThemes