Search results
From Filipino Engineer Wiki
- = Cable Sizing Calculation = ...ties, oversize cables will increase project costs, and improperly selected cable sizes will impact the operational efficiency of the electrical system.29 KB (4,658 words) - 04:55, 18 March 2023
- ...the same raceway, auxiliary gutter, cable tray, cablebus assembly, trench, cable, or cord, unless otherwise permitted in accordance with 3.0.1.3(b)(1) throu ...conductors shall comply with the provisions of 2.50.6.3. Parallel runs in cable tray shall comply with the provisions of 3.92.1.8(d).48 KB (6,917 words) - 12:24, 29 January 2024
- ...be insulated or covered. Conductors in cables or raceways, except Type MI cable, shall be of the rubber-covered type or thermoplastic type and, in wet loca ...onductors, and 8.0 mm 2 (3.2 mm dia.) copper or 14 mm 2 aluminum where in cable.28 KB (3,941 words) - 03:21, 8 March 2022
- ...be insulated or covered. Conductors in cables or raceways, except Type MI cable, shall be of the rubber-covered type or thermoplastic type and, in wet loca ...onductors, and 8.0 mm 2 (3.2 mm dia.) copper or 14 mm 2 aluminum where in cable.29 KB (3,988 words) - 08:59, 22 October 2023
- ...ting (mercury, fluorescent, or incandescent) desired together with general construction features will make possible computation of load using formulas in lighting ...leeway for changes in the outdoor lighting which may develop late in the construction period.31 KB (4,697 words) - 15:59, 17 April 2024
- ...the same raceway, auxiliary gutter, cable tray, cablebus assembly, trench, cable, or cord, unless otherwise permitted in accordance with 3.0.1.3(b)(1) throu ...conductors shall comply with the provisions of 2.50.6.3. Parallel runs in cable tray shall comply with the provisions of 3.92.1.8(d).57 KB (8,085 words) - 03:21, 8 March 2022
- :(3) Where installed in any vault that meets the construction requirements of Article 4.50.3. ====2.30.1.7 Other Conductors in Raceway or Cable. ====46 KB (6,413 words) - 03:52, 8 March 2022
- :(3) Where installed in any vault that meets the construction requirements of Article 4.50.3. ====2.30.1.7 Other Conductors in Raceway or Cable. ====46 KB (6,413 words) - 03:21, 8 March 2022
- ...of certain products to ensure that they meet the requirements of both the construction and general OSHA electrical standards. If the listing (product certificati ...Insulated Copper (or Aluminum) Conductors," are contained in the Insulated Cable Engineers Association's publication ICEA P-32-382.63 KB (9,124 words) - 03:45, 7 November 2022
- ...of certain products to ensure that they meet the requirements of both the construction and general OSHA electrical standards. If the listing (product certificati ...all be protected against permanent damage from the weather during building construction.56 KB (8,017 words) - 03:21, 8 March 2022
- ...combination of equipment grounding conductors, metallic raceways, metallic cable sheaths, electrical equipment, and any other electrically conductive materi | class="left" | Cable trays134 KB (19,565 words) - 03:52, 8 March 2022
- ...combination of equipment grounding conductors, metallic raceways, metallic cable sheaths, electrical equipment, and any other electrically conductive materi | class="left" | Cable trays134 KB (19,565 words) - 03:21, 8 March 2022
- :(a) They are contained within the same raceway or cable. ...or cables, the same number of conductors shall be used in each raceway or cable. Conductors of one phase, polarity, neutral, or grounded circuit conductor51 KB (5,907 words) - 03:21, 8 March 2022
- ...orarily subject to dampness or wetness, as in the case of a building under construction. ===== Service Cable. =====45 KB (6,446 words) - 14:44, 12 March 2023
- ...orarily subject to dampness or wetness, as in the case of a building under construction. ;Service Cable.38 KB (5,736 words) - 10:57, 2 November 2022
- ...e arc-fault circuit interrupter shall be installed in a metal raceway or a cable with a metallic sheath. :(1) Construction for the physically impaired48 KB (6,764 words) - 03:21, 8 March 2022
- ...e arc-fault circuit interrupter shall be installed in a metal raceway or a cable with a metallic sheath. :(1) Construction for the physically impaired51 KB (7,171 words) - 11:39, 20 August 2023